Viewer
SMARTDent V2
SMARTDent V3
Xelis Dental
OnDemand3D
RAYFace
RAYTeams
RealGuide
Invivo
LeafImplant
Zimmer
5D
Utility
Bluescreen Hotfix
CS Wizard
DBRecoveryTool
Dentrix Smart Image Setup
Disk Space Analyzer
OnDemand License Collect
OnDemand not opening
RayBridge
RayDVT
RayEMS
TeamViewer Host
Twack
Windows Update Blocker
Q-EVT
Driver
RIOSensor
RIOSensor +
Twain
RAYFace USB Driver
Xelis, OnDemand3D License Driver
Detector Driver
Packages — RAYSCAN α (25)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYSCAN α + (21)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYSCAN α + (new) (31)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYSCAN α 2D (new) (7)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYSCAN α 2DN (11)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYSCAN α 3D (new) (17)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYSCAN S & Studio (20)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAY PreMiere (6)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYSCAN S, Studio & Premiere (1)
Package folder per version. Tap Download to open the Dropbox folder.
Packages — RAYQuantum (3)
Package folder per version. Tap Download to open the Dropbox folder.
New Server PC Setup
Please ensure to back up DB! Do not proceed if anything goes wrong!
Old Server PC
- Ask IT to copy and paste the Scan data from the Old PC to the New PC D:\Ray\DICOMImage
- Backup the DB with DB Recovery tool Plan B Link
- Update the RAYServer to v2.3.7.3 Link
- Use CSWizard v2.1.0.3 and update the DB table Link
- Repeat step 2 and get the table updated version of backup file Plan A
New Server PC
- Rename the Ray folder to Ray_ Make sure the data was all copied over from Old Server PC
- Install RAYSever v2.3.7.3 and SMARTDent v2.3.5.3 Link
- Run SMARTDent and import an image to create an instance
- Run the DB Recovery tool and restore the DB
- Restart the PC
- Delete the Ray folder and rename the Ray_ to Ray folder
- Check if the DB is restored Use Plan B if not working
Acquisition PC
- Change the WebServer IP and SQLServer IP from 127.0.0.1 to the New Server PC IP Address C:\Ray\RAYSCANN\ConfigEditor.exe
- (CT Only) Change the RAYDent Connect IP from 127.0.0.1 to the New Server PC IP Address C:\Ray\RAYDENT Connect\RAYDENT Connect.exe
All Workstations
- Change the SMARTDent IP to the New Server PC IP Address
Acquisition PC
- Take a scan from the Acquisition PC
New Server PC
- Check if the image is saving in the New Server PC
Old Server PC
- Ask IT to copy and paste the Scan data from the Old PC to the New PC D:\Ray\DICOMImage
- Backup the DB with DB Recovery tool Plan C Link
- Update the RAYServer to v2.3.7.3 Link
- Use CSWizard v2.1.0.3 and update the DB table Link
- Run DB backup from CSWizard and get the SMARTDent v3 backup Plan A
- Repeat step 2 and get the table updated version of backup file Plan B
New Server PC
- Rename the Ray folder to Ray_ Make sure the data was all copied over from Old Server PC
- Install RAYSever v2.3.7.3 and SMARTDent v3.0.15.3 Link
- Take a scan from the Acquisition PC to create a DB table
- Use CSWizard v2.1.0.3 and restore the DB from step 5
- Run the DB Recovery tool and restore the DB
- Restart the PC
- Delete the Ray folder and rename the Ray_ to Ray folder
- Check if the DB is restored Use Plan B or Plan C if not working
Acquisition PC
- Change the WebServer IP and SQLServer IP from 127.0.0.1 to the New Server PC IP Address C:\Ray\RAYSCANN\ConfigEditor.exe
- (CT Only) Change the RAYDent Connect IP from 127.0.0.1 to the New Server PC IP Address C:\Ray\RAYDENT Connect\RAYDENT Connect.exe
All Workstations
- Change the SMARTDent IP to the New Server PC IP Address
Acquisition PC
- Take a scan from the Acquisition PC
New Server PC
- Check if the image is saving in the New Server PC
New Acquisiton PC Setup
Old PC
- PC and unit funtionality Test image of Pano, CT and Ceph
- Information of Old RAYSCAN Package version, 3D viewer, and PMS
- Backup RAYSCAN and Setting Wizard folder in D drive If you can access to the PC
- Backup of Patient Database and entire D drive Discuss with manger, DB recovery tool is needed Link
- (CT unit only) Check the license of the 3D viewer, Backup the SL key if needed Software License key must be backed up
New PC
- Check the PC Specification Based on the Unit SN
- RAYSCAN NIC setting
- Disable the UAC (User Account Countrol) setting
- Disable the Windows Defender Firewall
- Disable the Real-time Protection
- Update the Graphics Card Driver NVIDIA App
- (Win 11 Only) Enable the IIS setup https://docs.appeon.com/ps2022r2/Installing_IIS_in_Windows_11.html#:~:text=To%20install%20IIS%2C,the%20following%20features%20are%20selected.&text=Step%203%3A%20Click%20OK%20to%20install%20the%20selected%20features.
- Get the RAYSCAN Software Package based on the unit SN
- Install RAYServer and SMARTDent to check the server functionality
- Install RAYSCAN Scanner and image processing
- Install the Detector SDK Discuss with manger (GigE, Ebus, Vivix or no need)
- Check the unit code and update the FW of the board & THU Make sure to reboot the unit after FW update
- Check the unit alignment and calibration Discuss with manager
- (CT unit only) Install RayDVT or Q-EVT based on the unit SN
- (CT unit only) Install 3D viewer Xelis, OnDemand3D, RealGUIDE or Invivo
- (CT unit only) Check the license of the 3D viewer Xelis (Dongle), OnDemand (Dongle or SL)
- Rename the Diagnostic App and restart the PC C:\Ray\RayScanN\DiagnosisApp
- Check the unit funtionality Test image of Pano, CT (DVT test if possible) and Ceph
- Install RAY EMS based on the SN of the unit Ask Charlie for any question
- Disable the Windows Update by Windows Update Blocker Finish up the windows update if it was already running Link
- Install Twain Driver C:\Windows\twain_32 Link
- Check the connection of SMARTDent and 3D viewer from another workstations Please Guide how to connect their PMS or OMS
Xelis Installation Guide (Windows 10 & 11)
- Check if the dongle key is plugged in
- Download the Xelis installation package Link
- Install Xelis 1.0.6.2 BN15 Run exe from Xelis Dental folder
- Install Hasp driver Run install.bat from HASPDrvr folder
- Install Hasp License manager Run lmsetup.exe from HASPLicenseMan folder
- Run Xelis from SMARTDent